SPEX CERTIPREP -- INTERFERENCE CHECK STANDARD, INTER-18 (SUPPLEMENTAL) -- 6810-00D004417
=====================  Product Identification  =====================

Product ID:INTERFERENCE CHECK STANDARD, INTER-18 (SUPPLEMENTAL)
MSDS Date:04/15/1996
FSC:6810
NIIN:00D004417
=== Responsible Party ===
Company Name:SPEX CERTIPREP
Address:203 NORCROSS AVE
City:NETUCHEN
State:NJ
ZIP:08840
Country:US
Info Phone Num:201-549-7144
Emergency Phone Num:908-549-7144
Preparer's Name:SUSHA RAMANC
CAGE:04XT3
=== Contractor Identification ===
Company Name:SPEX CERTIPREP INC
Address:203 NORCROSS AVE
Box:City:METUCHEN
State:NJ
ZIP:08840
Country:US
Phone:732-549-7144
CAGE:04XT3
Company Name:SPEX CERTIPREP INC
Address:203 NORCROSS AVE
Box:City:METUCHEN
State:NJ
ZIP:08840
Country:US
Phone:732-549-7144
CAGE:07977

=============  Composition/Information on Ingredients  =============

Ingred Name:MANGANESE (SARA 313)
CAS:7439-96-5
RTECS #:OO9275000
Fraction by Wt: 200%PPM
Other REC Limits:NONE RECOMMENDED
OSHA PEL:C, 5 MG/M3 (FUME)
ACGIH TLV:0.2 MG/M3; 9596

Ingred Name:BERYLLIUM (SARA 313) (CERCLA)
CAS:7440-41-7
RTECS #:DS1750000
Fraction by Wt: 100%PPM
Other REC Limits:NONE RECOMMENDED
OSHA PEL:0.002 MG/M3, Z-2
ACGIH TLV:.002 MG/M3, A2; 9596

Ingred Name:MERCURY (SARA 313) (CERCLA)
CAS:7439-97-6
RTECS #:OV4550000
Fraction by Wt: 50%PPM
Other REC Limits:NONE RECOMMENDED
OSHA PEL:C, 0.1 MG/M3; Z-2
ACGIH TLV:S,0.025 MG/M3; A4;96
EPA Rpt Qty:1 LB
DOT Rpt Qty:1 LB

Ingred Name:NITRIC ACID (SARA 302/313) (CERCLA)
CAS:7697-37-2
RTECS #:QU5775000
Fraction by Wt: 5%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:2 PPM
ACGIH TLV:2 PPM/4 STEL; 9596
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

Ingred Name:ARSENIC TRIOXIDE (SARA 302/313) (CERCLA)
CAS:1327-53-3
RTECS #:CG3325000
Fraction by Wt: 0.1%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:SEE 1910.1018
ACGIH TLV:0.01 MG/M3, A1; 9596
EPA Rpt Qty:1 LB
DOT Rpt Qty:1 LB

Ingred Name:POTASSIUM NITRATE
CAS:7757-79-1
RTECS #:TT3700000
Fraction by Wt: 2%
Other REC Limits:NONE RECOMMENDED

Ingred Name:WATER
CAS:7732-18-5
RTECS #:ZC0110000
Fraction by Wt: 90-95%
Other REC Limits:NONE RECOMMENDED

Ingred Name:POTASSIUM SALT, 20000PPM
Fraction by Wt: SEE ING
Other REC Limits:NONE RECOMMENDED

Ingred Name:LEAD (SARA 313) (CERCLA)
CAS:7439-92-1
RTECS #:OF7525000
Fraction by Wt: 1000%PPM
Other REC Limits:NONE RECOMMENDED
OSHA PEL:SEE 1910.1025
ACGIH TLV:0.05MG/M3, A3; 9596
EPA Rpt Qty:1 LB
DOT Rpt Qty:1 LB

Ingred Name:THALLIUM (SARA 313) (CERCLA)
CAS:7440-28-0
RTECS #:XG3425000
Fraction by Wt: 1000%PPM
Other REC Limits:NONE RECOMMENDED
OSHA PEL:S, 0.1 MG/M3
ACGIH TLV:S, 0.1 MG/M3; 9596
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

Ingred Name:SELENIUM (SARA 313) (CERCLA)
CAS:7782-49-2
RTECS #:VS7700000
Fraction by Wt: 500%PPM
Other REC Limits:NONE RECOMMENDED
OSHA PEL:0.2 MG/M3
ACGIH TLV:0.2 MG/M3; 9596
EPA Rpt Qty:1 LB
DOT Rpt Qty:1 LB

Ingred Name:BARIUM (SARA 313)
CAS:7440-39-3
RTECS #:CQ8370000
Fraction by Wt: 300%PPM
Other REC Limits:NONE RECOMMENDED
OSHA PEL:0.5 MG/M3

Ingred Name:CADMIUM (SARA 313) (CERCLA)
CAS:7440-43-9
RTECS #:EU9800000
Fraction by Wt: 300%PPM
Other REC Limits:NONE RECOMMENDED
OSHA PEL:0.2 MG/M3 DUST; Z-2
ACGIH TLV:0.01 MG/M3 DUST;9596
EPA Rpt Qty:10 LBS
DOT Rpt Qty:10 LBS

Ingred Name:CHROMIUM (SARA 313) (CERCLA)
CAS:7440-47-3
RTECS #:GB4200000
Fraction by Wt: 300%PPM
Other REC Limits:NONE RECOMMENDED
OSHA PEL:1 MG/M3
ACGIH TLV:0.5 MG/M3; 9596
EPA Rpt Qty:1 LB
DOT Rpt Qty:1 LB

Ingred Name:COBALT (SARA 313)
CAS:7440-48-4
RTECS #:GF8750000
Fraction by Wt: 300%PPM
Other REC Limits:NONE RECOMMENDED
OSHA PEL:0.1 MG/M3
ACGIH TLV:0.02 MG/M3; A3; 9596

Ingred Name:COPPER (SARA 313) (CERCLA)
CAS:7440-50-8
RTECS #:GL5325000
Fraction by Wt: 300%PPM
Other REC Limits:NONE RECOMMENDED
OSHA PEL:0.1MG/M3 FUME/1 DUST
ACGIH TLV:0.2 MG/M3 FUME; 9596
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS

Ingred Name:NICKEL (SARA 313) (CERCLA)
CAS:7440-02-0
RTECS #:QR5950000
Fraction by Wt: 300%PPM
Other REC Limits:NONE RECOMMENDED
OSHA PEL:1 MG/M3
ACGIH TLV:1 MG/M3; 9596

Ingred Name:SILVER (SARA 313) (CERCLA)
CAS:7440-22-4
RTECS #:VW3500000
Fraction by Wt: 300%PPM
Other REC Limits:NONE RECOMMENDED
OSHA PEL:0.01 MG/M3
ACGIH TLV:0.1 MG/M3; 9596
EPA Rpt Qty:1 LB
DOT Rpt Qty:1 LB

Ingred Name:VANADIUM (SARA 313)
CAS:7440-62-2
RTECS #:YW1355000
Fraction by Wt: 300%PPM
Other REC Limits:NONE RECOMMENDED

Ingred Name:ZINC (SARA 313) (CERCLA)
CAS:7440-66-6
RTECS #:ZG8600000
Fraction by Wt: 300%PPM
Other REC Limits:NONE RECOMMENDED
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:YES    IARC:YES	  OSHA:YES
Health Hazards Acute and Chronic:CONCEN HNO3:FATAL IF TOO MUCH
    INHAL/ABSORB THRU SKIN.VAP/MIST IRRIT EYE/MUC MEMB/SKIN.EYE:SEVERE
    BURNS RESULTS IN PERM DMG/VISUAL IMPAIR.SKIN:IMMED SEVERE,PENETRAT
    BURNS,DEEP ULCERS,STAIN SKIN BRIGHT  YELLOW/YELLOWISH BROWN
    COLOR,ERODE TEETH.INGEST:IMMED PAIN,BURNS,MOUTH/ESOPHAGUS/GI
    TRACT.INHAL:SPASM,INFLAMM/(SIGN/SYP)
Explanation of Carcinogenicity:PER MSDS:ARSENIC SALTS CARC ACCORDINT TO
    OSHA/NTP/IARC.CONTAINS CHEM IN PROP 65 CA.
Effects of Overexposure:HEALTH:EDEMA OF LARYNX/BRONCHI,CHEM
    PNEUITIS,PULM EDEMA.SYMPTOMS:BURN
    SENS,COUGH,WHEEZING,LARYNGITIS,SHORTNESS OF
    BREATH,HEAD,NAU,VOMIT.SOLN HARMFUL IF INHAL/INGEST/CONTACT
    SKIN/EYE.ARSENCI CMPDS:RESP  CANC(BELIEVE NEEDS
    PROMOTER),DEATH,HYPERSENSITIVITY PNEUOITIS.KNO3:HARMFUL IF
    INHAL/INGEST/IRRIT IF CONTACT EYE/SKIN.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

=======================  First Aid Measures  =======================

First Aid:EYE:FLUSH W/WATER FOR @LEAST 15MINS LIFTING
    EYELIDS.SKIN:REMOVE CONTAMIN CLOTH.FLUSH W/WATER FOR @LEAST
    15MINS.INHAL:MOVE TO FRESH AIR.INGEST:DO NOT INDUCE VOMIT.GET IMMED
    MED HELP.PATIENT CONSC GIVE  LG QUANT OF WATER OR MILK.IRRIT CONTS
    GET MED ATTN IMMED.

=====================  Fire Fighting Measures  =====================

Flash Point:NA
Autoignition Temp:Autoignition Temp Text:NP
Lower Limits:NP
Upper Limits:NP
Extinguishing Media:APPROPRIATE TO SURROUNDING FIRE CONDITIONS.
Fire Fighting Procedures:NONE SPECIFIED BY MANUFACTURER.
Unusual Fire/Explosion Hazard:CONCEN HNO3 REACTS EXPLO W/COMBUST ORG OR
    READILY OXIDIZABLE MATLS SUCH AS ALCOHOL,WOOD,TURPENTINE,METAL
    POWDERS,HYDROGEN SULFIDE,ETC.CONCEN HNO3 NOT (SUPPLEME)

==================  Accidental Release Measures  ==================

Spill Release Procedures:VENTI AREA.DILUTE W/WATER,NEUTRALIZE W/SODA
    ASH,LIMESTONE,ETC.WIPE UP/PUT INTO SEALED CNTNR FOR PROPER
    DISPO.WASH SPILL SITE OFF W/WATER AFT MATL PICKUP COMPLETE.WEAR
    CHEM RESISTANT GLASSES,GLOVES,CLO THING.WEAR MSHA/NIOSH APPROVED
    RESPIRATOR.
Neutralizing Agent:SODA ASH, LIMESTONE, ETC.

======================	Handling and Storage  ======================

Handling and Storage Precautions:CONCEN NITRIC ACID WILL ATTACK SOME
    FORMS OF PLASTICS,RUBBER,COATINGS.STORE @RM TEMP.KEEP TIGHTLY CLSD
    WHEN NOT IN USE.
Other Precautions:HAVE IMMED AVAILABILITY OF EYEWASH IN CASE OF
    EMERGENCY.AVOID INHAL/INGEST/CONTACT W/EYE/SKIN.SYMPTOMS/HEALTH HAZ
    FOR DIL HNO3 EXPECTED TO BE LESS SEVERE THAN EXPO TO CONCEN
    HNO3.HOWEVER IT'S IN SOLN  @1%(10000PPM)/> CONCEN EFFECTS GIVEN.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:MSHA/NIOSH APPROVED RESPIRATOR.
Ventilation:CHEMICAL HUME HOOD.
Protective Gloves:YES.
Eye Protection:GOGGLES.
Other Protective Equipment:EYEWASH,LAB COAT.
Work Hygienic Practices:WASH CONTAMIN CLOTH BEF REUSE.WASH CAREFULLY
    AFT USE.
Supplemental Safety and Health
4-PART KIT,SEE PNIND:B,C,E.KEY1=C1. EXPLO/FIRE:COMBUST BUT STRONG
    OXIDIZER;IT'S HEAT OF REACTION W/RED AGENTS/COMBUST MAY CAUSE
    IGN.CAN RX W/METALS TO RELEASE FLAMM HYDROGEN GAS.

==================  Physical/Chemical Properties  ==================

HCC:C1
Boiling Pt:B.P. Text:NP
Melt/Freeze Pt:M.P/F.P Text:NP
Decomp Temp:Decomp Text:NP
Vapor Pres:NP
Vapor Density:NP
Spec Gravity:1
pH:NP
Viscosity:NP
Evaporation Rate & Reference:NP
Solubility in Water:SOLUBLE.
Appearance and Odor:TRANSPARENT WITH AN ACRID ODOR.
Percent Volatiles by Volume:NP
Corrosion Rate:NP

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
STRONG BASES(VIOLENT SPLATTER),ORG/READILY OXIDIZABLE
    MATLS(ALCOHOL,WOOD,TURPENTINE,METAL POWDERS,HYDROGEN SULFIDE,ETC).
Stability Condition to Avoid:ELEVATED TEMPERATURES MAY CAUSE CONTAINERS
    TO BURST & LIBERATE TOXIC OXIDES OF NITROGEN.
Hazardous Decomposition Products:WILL RELEASE TOXIC NITROGEN OXIDE
    FUMES & VAPORS.

====================  Disposal Considerations  ====================

Waste Disposal Methods:CONTACT LOCAL HAZARDOUS OR CHEMICAL WASTE
    DISPOSAL AGENCY FOR REGULATIONS.SOLN SUBJ TO REPORTING REQMTS OF
    SEC 313 SARA TITLE III/40CFR372.INGREDS <10000PPM(1%) OR
    1000PPM(0.1%) NOT REQUIRED TO BE REP ORTED AS HAZ INGREDS ACCORDING
    TO OSHA.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.