ORION RESEARCH INCORPORATED -- REFERENCE ELECTRODE FILL SOLUTION (90001) -- 6850-00N008988
=====================  Product Identification  =====================

Product ID:REFERENCE ELECTRODE FILL SOLUTION (90001)
MSDS Date:03/19/1986
FSC:6850
NIIN:00N008988
=== Responsible Party ===
Company Name:ORION RESEARCH INCORPORATED
Address:529 MAIN STREET
City:BOSTON
State:MA
ZIP:02129
Emergency Phone Num:617-242-3900
Preparer's Name:REGULATORY AFFAIR CHEMIST
CAGE:30260
=== Contractor Identification ===
Company Name:ORION RESEARCH INC
Address:529 MAIN ST
Box:City:BOSTON
State:MA
ZIP:02129
Country:US
Phone:617-242-3900
CAGE:30260

=============  Composition/Information on Ingredients  =============

Ingred Name:POTASSIUM NITRATE
CAS:7757-79-1
RTECS #:TT3700000
Fraction by Wt: 17.2%
Other REC Limits:N/K 
OSHA PEL:N/K 
ACGIH TLV:N/K 

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:N/K 
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:INGEST:INGEST OF LARGE AMOUNTS CAN
    CAUSE VIOLENT GASTROENTERITIS.PROLONGED EXPOSURE TO SMALL AMOUNTS
    MAY PRODUCE
    ANEMIA,METHEMOGLOBINEMA,NEPHRITIS.INHAL:N/K.SKIN:N/K.EYES:N/K.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:N/K 
Medical Cond Aggravated by Exposure:N/K 

=======================  First Aid Measures  =======================

First Aid:INHAL:REMOVE TO FRESH AIR.SUPPORT BREATHING (GIVE O*2/ARTF
    RESP) .SKIN & EYES:WASH AFFECTED AREAS W/ WATER FOR AT LEAST 15
    MINUTES.INGEST:CALL MD IMMEDIATELY .

=====================  Fire Fighting Measures  =====================

Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA AND FULL
    PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NITRATE MAY RENDER OTHER MATERIALS MORE
    COMBUSTIBLE IF ALLOWED TO DRY OUT UPON THEM.UPON THERMAL
    DECOMPOSITION OXIDES OF NITROGEN ARE RELEASED.

==================  Accidental Release Measures  ==================

Spill Release Procedures:WASH DOWN DRAIN WITH EXCESS WATER IF LOCAL
    LAWS ALLOW.
Neutralizing Agent:N/K .

======================	Handling and Storage  ======================

Handling and Storage Precautions:KEEP WELL SEALED AND COOL.
Other Precautions:N/K 

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
    EXPOSURE OF CONCERN .
Ventilation:USE MECHANICAL (GENERAL) TO KEEP CONCENTRATION IN AIR LOW.
Protective Gloves:RUBBER GLOVES.
Eye Protection:SAFETY GLASSES.
Other Protective Equipment:N/K .
Work Hygienic Practices:N/K 
Supplemental Safety and Health
N/K 

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:>100C,212F
Melt/Freeze Pt:M.P/F.P Text:-4C,25F
Decomp Temp:Decomp Text:N/K 
Spec Gravity:1 (WATER=1)
pH:6-7.5
Solubility in Water:MISCIBLE
Appearance and Odor:LIQUID.
Percent Volatiles by Volume:0

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
N/K 
Hazardous Decomposition Products:OXIDES OF NITROGEN UPON THERMAL
    DECOMPOSITION.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSAL MUST BE IN ACCORDANCE WITH
    FEDERAL,STATE & LOCAL REGULATIONS .

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.